DB2 - Problembeschreibung
Problem IC65595 | Status: Geschlossen |
A ONLINE backup using /INCLUDE/LOGS fails with SQL2428N and "Log could not be retrieved" in the db2diag.log. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
A backup, which includes log files, may fail if the log files that the backup needs are archived. Backup processing can timeout waiting for archived log files to be moved from the physical archive, if the files are large. You will come across the following error messages from the db2diag.log: 2010-01-08-02.06.01.052413-300 I76730A364 LEVEL: Warning PID : 123456 TID : 1234 PROC : db2sysc 0 INSTANCE: db2inst1 NODE : 000 EDUID : 1234 EDUNAME: db2logmgr (SAMPLE) 0 FUNCTION: DB2 UDB, data protection services, sqlpgRetrieveLogFile, probe:4130 MESSAGE : Started retrieve for log file S0000464.LOG. 2010-01-08-02.06.11.592397-300 I77095A518 LEVEL: Error PID : 123456 TID : 1111 PROC : db2sysc 0 INSTANCE: db2inst1 NODE : 000 DB : SAMPLE APPHDL : 0-12212 APPID: *LOCAL.db2inst1.100108021230 AUTHID : TESTUSER EDUID : 1111 EDUNAME: db2bm.421213.20 (SAMPLE) 0 FUNCTION: DB2 UDB, data protection services, sqlpOpenLogForBackup, probe:20 RETCODE : ZRC=0x82100016=-2112880618=SQLPLFR_RC_RETRIEVE_FAILED "Log could not be retrieved" | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * The retrieval processing was not fast enough and the * * backupprocessing assumes that the necessary log files will * * beready but fails when it could not find one of the files. * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 Version 9.7 Fix Pack 2. * **************************************************************** | |
Local-Fix: | |
Be sure that archived log files that the backup needs are available before the backup is attempted. | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows | |
Lösung | |
First fixed in DB2 Version 9.7 Fix Pack 2. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC66808 IC69324 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 15.01.2010 25.05.2010 25.05.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP2 | |
Problem behoben lt. FixList in der Version | |