DB2 - Problembeschreibung

Problem IC66188 Status: Geschlossen

"MULTIPLE PRODUCTS" INSTALLATION SHOULD NOT BE ALLOWED BY
"DB2_INSTALL" COMMAND IN INTERACTIVE MODE

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When you launch "db2_install" without any parameters, it starts 
in interactive mode and you will see the following message: 
====================================================== 
Specify one of the following keywords to install DB2 products. 
 
  ESE 
  CONSV 
  WSE 
  CLIENT 
  RTCL 
====================================================== 
 
The displayed message clearly states that you must select only 
one product. 
However, if you enter more than one product,  for example "ESE 
RTCL" or  "CLIENT ESE", no error is returned and the 
installation will finish successfully. 
 
The result of selecting "multiple products" is unpredictable and 
you might find some files missing from the 
installation path. For example selecting "ESE RTCL" might result 
in the installation of "RTCL" only. 
 
After applying the fix provided by this APAR you will receive an 
error if you select "multiple products". You will not be able to 
enter more than one product.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users of version 9.7 on Linux, Unix and                  * 
* Windowsplatforms.                                            * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* When you launch "db2_install" without any                    * 
* parameters,itstarts in interactive mode and you will see     * 
* thefollowingmessage:========================================== 
* of the following keywords to                                 * 
* installDB2products.ESECONSVWSECLIENTRTCL====================== 
* message clearly states that you must selectonlyone           * 
* product.However, if you enter more than one product,         * 
* forexample"ESE RTCL" or "CLIENT ESE", no error is returned   * 
* andtheinstallation will finish successfully.The result       * 
* ofselecting "multiple products" is unpredictableand you      * 
* mightfind some files missing from the installationpath.      * 
* Forexample selecting "ESE RTCL" might result in              * 
* theinstallationof "RTCL" only.After applying the fix         * 
* provided by this APARyou willreceive an error if you select  * 
* "multiple products".You willnot be able to enter more than   * 
* one product.                                                 * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 UDB Version 9.7 Fix Pack 2 or higher levels.  * 
****************************************************************
Local-Fix:
Enter only one keyword when you are prompted to specify the 
product you want to install.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 UDB Version 9.7 Fix Pack 2.
Workaround
Enter only one keyword when you are prompted to specify the 
product you want to install.
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC71754 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
10.02.2010
25.05.2010
25.05.2010
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP2
Problem behoben lt. FixList in der Version
9.7.0.2 FixList