DB2 - Problembeschreibung

Problem IC67137 Status: Geschlossen

POOL_ASYNC_WRITE_TIME AND POOL_WRITE_TIME MONITOR ELEMENTS MAY BE LARGER
THAN THE ACTUAL VALUE.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Buffer pool asynchronous write time monitor element 
(pool_async_write_time )  may be larger than the actual value. 
Since total buffer pool physical write time ( pool_write_time) 
includes the value of the pool_async_write_time monitor element, 
the value of pool_write_time can also be larger than the actual 
value.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* all platform                                                 * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* Buffer pool asynchronous write time monitor element          * 
* (pool_async_write_time )  may be larger than the actual      * 
* value. Since total buffer pool physical write time (         * 
* pool_write_time)  includes the value of the                  * 
* pool_async_write_time monitor element, the value of          * 
* pool_write_time can also be larger than the actual value.    * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to V9.7 FP2.                                         * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
V9.7 FP2 will contain the fix.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC67209 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
11.03.2010
23.04.2010
23.04.2010
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP2
Problem behoben lt. FixList in der Version
9.7.0.2 FixList