Neueste VersionenFixList
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

DB2 - Problembeschreibung

Problem IC68410 Status: Geschlossen

ON WIN64, FRAMEWORK64 MACHINE.CONFIG ISN'T UPDATED AT ALL AFTER
INSTALLATION

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
After the installation of a 64-bit product, the 64-bit version 
of machine.config 
(C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\CONFIG\machine. 
config) 
isn't updated properly. 
 
Some .NET applications may fail to load.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* .NET applications on Windows                                 * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* After the installation of a 64-bit product, the 64-bit       * 
* version of machine.config                                    * 
* (C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\CONFIG\machin 
* isn't updated properly.                                      * 
*                                                              * 
* Some .NET applications may fail to load.                     * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to Version 9.5 Fix Pack 6 or later.                  * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 6a for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem was first fixed in Version 9.5 Fix Pack 6.
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
04.05.2010
19.07.2010
19.07.2010
Problem behoben ab folgender Versionen (IBM BugInfos)
9.5.FP6
Problem behoben lt. FixList in der Version