DB2 - Problembeschreibung

Problem IC69456 Status: Geschlossen

HEALTH MONITOR PROVIDES ALERT WHEN MONITOR HEAP SET TO AUTOMATIC.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Alert shows: 
 
ADM10500E Health indicator "Monitor Heap Utilization" 
("db2.mon_heap_util") breached the 
"upper" alarm threshold of "XX %" with value "XXX %" on 
"instance" "DB2". Calculation: 
 
Health Monitor is sending Alert to db2 user while Monitor Heap 
is set to Automatic. This APAR will fix the code in such a way 
that 
the health monitor code , by default will not monitor these 
health indicators. For those users who don't have the 
MON_HEAP_SZ 
to 'AUTOMATIC' and they want these health indicator alarms, they 
can enable using   "update alert cfg "  command.
Problem-Zusammenfassung:
Local-Fix:
You can turn off the Monitor Alert switch by doing following: 
 
db2 update alert cfg for database manager using 
db2.mon_heap_util  set  THRESHOLDSCHECKED  NO 
db2 update alert cfg for databases using db.db_heap_util  set 
THRESHOLDSCHECKED  NO
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Kommentar
This APAR is a duplicate of IC69453