DB2 - Problembeschreibung

Problem IC70494 Status: Geschlossen

HADR Standby may trap during restart operation

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
While restarting the HADR standby, a trap could happen during 
replay if a table has been dropped and is in pending drop during 
the replay.  The db2diag.log msg will be reported as shown. 
 
 
2010-01-27-19.48.16.913908+060 I13060576A356      LEVEL: Severe 
PID     : 553014               TID  : 1           PROC : 
db2pfchr 0 
INSTANCE: db2ap1               NODE : 000 
FUNCTION: DB2 UDB, trace services, sqlt_logerr_string, probe:0 
MESSAGE : sqldDeassertObjExists FAILS. 
DATA #1 : String, 52 bytes 
original object life LSN != current object life LSN.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* DB2 Version 9.5 servers from GA through to Fix Pack 6        * 
* onLinux, Unix and Windows platforms.                         * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* While restarting the HADR standby, a trap could happenduring * 
* replay if a table has been dropped and is in pendingdrop     * 
* during the replay.  The db2diag.log msg will bereported as   * 
* shown.2010-01-27-19.48.16.913908+060 I13060576A356           * 
* LEVEL:SeverePID    : 553014              TID  : 1            * 
* PROC :db2pfchr 0INSTANCE: db2ap1              NODE :         * 
* 000FUNCTION: DB2 UDB, trace services,                        * 
* sqlt_logerr_string,probe:0MESSAGE : sqldDeassertObjExists    * 
* FAILS.DATA #1 : String, 52 bytesoriginal object life LSN !=  * 
* current object life LSN.                                     * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 v9.5 FP7.                                     * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem has been fixed in DB2 v9.5 FP7.
Workaround
keiner bekannt / siehe Local-Fix