home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Neueste VersionenFixList
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

DB2 - Problembeschreibung

Problem IC71120 Status: Geschlossen

VISUAL EXPLAIN CRASHES WHEN ACCESS PLAN CONTAINS AN ISCAN.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When we try to get the access plan from Visual Explain for a 
query that contains an IXSCAN, Visual Explain crashes. An 
example of a simple query that exhibits this behaviour is: 
 
SELECT POLICY FROM SYSTOOLS.POLICY 
 
Using Visual Explain, the client v9x talks to the server 
instance v91 fp9, and Visual Explain crashes. 
 
You can verify if you are encountering this problem by obtaining 
a db2exfmt explain of the query: 
1) ensure the explain tables have been created, if not 
previously used: 
  - connect to the database, and use "db2 -tvf 
sqllib/misc/EXPLAIN.DDL" 
2) connect to the database, and generate the explain for the 
query using the explain statement: 
  - explain plan for ...sql_statement... 
  - where "...sql_statement..." is replaced by the sql statement 
that you want to check. 
3) use the db2exfmt utility to format the generated plan: 
  - db2exfmt -d ...db_name... -1 -o check_plan.exfmt 
  - where "...db_name..." is replaced with the database name. If 
password authentication is needed, you may be prompted for a 
userid and password. 
4) edit or grep the explain format utility's out to determine if 
there is an IXSCAN operator: 
  - grep IXSCAN check_plan.exfmt 
5) If the above check indicates there is one or more IXSCAN 
operators found in the explain, then you have encountered this 
APAR.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* When we try to get the access plan from Visual Explain for a * 
* query that contains an IXSCAN, Visual Explain crashes.       * 
*                                                              * 
* You can verify if you are encountering this problem by       * 
* obtaining a db2exfmt explain of the query:                   * 
*                                                              * 
* 1) ensure the explain tables have been created, if not       * 
* previously used:                                             * 
*                                                              * 
* - connect to the database, and use "db2 -tvf                 * 
* sqllib/misc/EXPLAIN.DDL"                                     * 
*                                                              * 
* 2) connect to the database, and generate the explain for the * 
* query using the explain statement:                           * 
*                                                              * 
* - explain plan for ...sql_statement...                       * 
* - where "...sql_statement..." is replaced by the sql         * 
* statement that you want to check.                            * 
*                                                              * 
* 3) use the db2exfmt utility to format the generated plan:    * 
*                                                              * 
* - db2exfmt -d ...db_name... -1 -o check_plan.exfmt           * 
* - where "...db_name..." is replaced with the database        * 
* name. If password authentication is needed, you may be       * 
* prompted for a userid and password.                          * 
*                                                              * 
* 4) edit or grep the explain format utility's out to          * 
* determine if there is an IXSCAN operator:                    * 
*                                                              * 
* - grep IXSCAN check_plan.exfmt                               * 
*                                                              * 
* 5) If the above check indicates there is one or more IXSCAN  * 
* operators found in the explain, then you have encountered    * 
* this APAR.                                                   * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to version 9.7 FixPack4                              * 
****************************************************************
Local-Fix:
Use the db2exfmt utility, or the Optim tools (for DB2 V9.1 and 
on), to obtain the explain instead of Visual Explain.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
This was first fixed by V97 FP4
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
13.09.2010
02.05.2011
02.05.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.,
9.7.FP4
Problem behoben lt. FixList in der Version
9.7.0.4 FixList