DB2 - Problembeschreibung
Problem IC73257 | Status: Geschlossen |
IF -M IS ANYWHERE IN THE SETUP.EXE COMMAND IT WILL BE TAKEN AS THE -M PARAMETER | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
If the string of "-m" is put in anywhere in the setup.exe command, such as in a file name of the install log or response file, it will be taken as the -m parameter, even you do not intend to specify that option in the install command. Then, some basic UI will be displayed during the silent install, such as the setup progress wizard. For example look at this command: setup.exe /f /l "D:\TEMP\Migrate-9.5_9.7.3a.log" /t "D:\TEMP\Migrate-9.5_2_9.7.3a-trace.log" /u "D:\TEMP\Setup-9.7-Client-RTC-mig.rsp" Since "-m" is part of the response file name used in the silent install, it is picked up as the -m parameter. Thus, the UI level of the silent install is set as BASIC_UI, where the setup progress wizard will be displayed. On Windows 7 systems, some error/warning message might be popped up because of this UI level. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users that try to install DB2 v9.7 and have -m somewhere in * * a path. * **************************************************************** * PROBLEM DESCRIPTION: * * If the string of "-m" is put in anywhere in the setup.exe * * * * command, such as in a file name of the install log or * * response * * file, it will be taken as the -m parameter, even you do not * * * * intend to specify that option in the install command. Then, * * some * * basic UI will be displayed during the silent install, such * * as * * the setup progress wizard. * * * * * * * * For example look at this command: * * * * * * * * setup.exe /f /l "D:\TEMP\Migrate-9.5_9.7.3a.log" * * * * /t "D:\TEMP\Migrate-9.5_2_9.7.3a-trace.log" * * * * /u "D:\TEMP\Setup-9.7-Client-RTC-mig.rsp" * * * * * * * * * * * * Since "-m" is part of the response file name used in the * * silent * * install, it is picked up as the -m parameter. Thus, the UI * * level * * of the silent install is set as BASIC_UI, where the setup * * * * progress wizard will be displayed. On Windows 7 systems, * * some * * error/warning message might be popped up because of this UI * * * * level. * **************************************************************** * RECOMMENDATION: * * Do not put "-m" in the path and file names specified in the * * * * install command line. * **************************************************************** | |
Local-Fix: | |
Do not put "-m" in the path and file names specified in the install command line. | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows | |
Lösung | |
Fixed from fixpack 5 of DB2 v9.7. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 14.12.2010 03.01.2012 03.01.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7. | |
Problem behoben lt. FixList in der Version | |
9.7.0.5 |