DB2 - Problembeschreibung
| Problem IC75107 | Status: Geschlossen |
QUERY RETURNS INCORRECT RESULT WHEN INTRA-PARTITION PARALLELISM IS USED | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / 950 - DB2 | |
| Problembeschreibung: | |
A query that used to work fine in V9.1 returns incorrect result
in V9.7. For example:
SELECT * FROM myschema.tbl1
WHERE C1 = 'X'
AND C2 = 'Y'
AND C3 IN ('A', 'B', 'C', 'D', 'E', 'F', 'G', 'H' )
AND C4 = 'V'
AND '2010-01-01' BETWEEN C5 AND C6
AND C7 = 'Z'
AND C8 = '0'
FETCH FIRST 1 ROWS ONLY
The query fails to return any rows even though two rows satisfy
the predicate criteria. If the "fetch first" option is removed,
or "fetch first 2 rows only" is used, the query returns two rows
as expected.
The problem occurs when the following conditions are true:
- Intra-partition parallelism is on
- Query degree is greater than 1
- Index scan is used
- Runstats has been performed against the table and indexes | |
| Problem-Zusammenfassung: | |
Fix delivered in V9.5 Fixpack 5. | |
| Local-Fix: | |
Disable intra-partition parallelism (may affect performance of other queries) | |
| verfügbare FixPacks: | |
DB2 Version 9.5 Fix Pack 8 for Linux, UNIX, and Windows | |
| Lösung | |
Fix delivered in V9.5 Fixpack 5. | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 22.03.2011 05.07.2011 05.07.2011 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.5.FP5 | |
| Problem behoben lt. FixList in der Version | |
| 9.5.0.8 |
|