DB2 - Problembeschreibung

Problem IC75107 Status: Geschlossen

QUERY RETURNS INCORRECT RESULT WHEN INTRA-PARTITION PARALLELISM IS USED

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
A query that used to work fine in V9.1 returns incorrect result 
in V9.7. For example: 
 
SELECT * FROM myschema.tbl1 
WHERE C1 = 'X' 
  AND C2 = 'Y' 
  AND C3 IN ('A', 'B', 'C', 'D', 'E', 'F', 'G', 'H' ) 
  AND C4 = 'V' 
  AND '2010-01-01' BETWEEN C5 AND C6 
  AND C7 = 'Z' 
  AND C8 = '0' 
FETCH FIRST 1 ROWS ONLY 
 
The query fails to return any rows even though two rows satisfy 
the predicate criteria. If the "fetch first" option is removed, 
or "fetch first 2 rows only" is used, the query returns two rows 
as expected. 
 
The problem occurs when the following conditions are true: 
 
- Intra-partition parallelism is on 
- Query degree is greater than 1 
- Index scan is used 
- Runstats has been performed against the table and indexes
Problem-Zusammenfassung:
Fix delivered in V9.5 Fixpack 5.
Local-Fix:
Disable intra-partition parallelism (may affect performance of 
other queries)
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Fix delivered in V9.5 Fixpack 5.
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
22.03.2011
05.07.2011
05.07.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
9.5.FP5
Problem behoben lt. FixList in der Version
9.5.0.8 FixList