DB2 - Problembeschreibung

Problem IC75650 Status: Geschlossen

AFTER CONNECTION IS REROUTED, SEAMLESS ACR IS NOT DRIVEN EVEN IF ALL
CONDITIONS FOR SEAMLESS ACR IS TRUE.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When CLI application using sysplex setup. After Failover, 
connection is rerouted successfully but Seamless ACR is not 
driven even if all conditions for seamless ACR is TRUE. 
 
 
Fix : 
 
After Failover happens and connection is rerouted successfully, 
Drive Seamless ACR if all the conditions holds good for 
Seamless.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* CLI users using ACR feature.                                 * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* When CLI application using sysplex setup. After Failover,    * 
*                                                              * 
* connection is rerouted successfully but Seamless ACR is not  * 
*                                                              * 
* driven even if all conditions for seamless ACR is TRUE.      * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to db2_v97fp5 or later releases.                     * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Fix : 
 
After Failover happens and connection is rerouted successfully, 
Drive Seamless ACR if all the conditions holds good for 
Seamless.
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
07.04.2011
08.12.2011
08.12.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
9.7.0.5 FixList