DB2 - Problembeschreibung
Problem IC77426 | Status: Geschlossen |
DB2 MAY HANG DUMPING THE LOCKLIST DURING ABNORMAL SHUTDOWN | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
During an abnormal termination, DB2 may hang during the diagnostic data collection. The problem occurs while collecting the locklist information. You will see a message similar to the following written to the db2diag.log before the hang occurs: 2011-07-08-12.31.53.877377-240 I66823E602 LEVEL: Severe PID : 4843 TID : 47351670499648PROC : db2sysc INSTANCE: dummy1 NODE : 000 DB : SAMPLE APPHDL : 0-48 APPID: *LOCAL.lorysa.110708162945 AUTHID : DUMMY EDUID : 90 EDUNAME: db2agent (SAMPLE) FUNCTION: DB2 UDB, trace services, sqlt_logerr_string (secondary logging fu, probe:0 MESSAGE : locklist DATA #1 : String, 130 bytes Check /home/hotel60/lorysa/sqllib/db2dump/FODC_Trap_2011-07-08-12.31.5 3.672240_0000/02171293.000.locklist.txt for additional data. The FODC directory will be created, and the locklist file will be incomplete. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * DB2 may hang during diagnostic data collection after an * * unexpected error, such as a trap. * **************************************************************** * RECOMMENDATION: * * Upgrade to the latest fix pack. * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in DB2 UDB version 9.7 fix pack 5. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 08.07.2011 08.12.2011 08.12.2011 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP5 | |
Problem behoben lt. FixList in der Version | |
9.7.0.5 |