DB2 - Problembeschreibung

Problem IC77432 Status: Geschlossen

DB2SUPPORT FAILS TO COLLECT DB2DIAG.LOG WHEN THE DIAGPATH IS SET IN
DB2CLI.INI FILE IN DS DRIVER PACKAGE.

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
DB2 data collection tool 'db2support' fails to collect the 
db2diag.log when the DIAGPATH variable is 
set to a different directory in the db2cli.ini file in Data 
Server driver package. The tool collects the db2diag.log only 
from <install dir>/db2dump which is the default directory for 
db2diag.log.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All DB2 V9.5 Data Server Driver users.                       * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* DB2 data collection tool 'db2support' fails to collect the   * 
* db2diag.log when the DIAGPATH variable is                    * 
* set to a different directory in the db2cli.ini file in Data  * 
* Server driver package. The tool collects the db2diag.log     * 
* only from <install dir>/db2dump which is the default         * 
* directory for db2diag.log.                                   * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to V9.5 FP9.                                         * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
The issue is first fixed in V9.5 FP9.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC78770 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
08.07.2011
04.04.2012
04.04.2012
Problem behoben ab folgender Versionen (IBM BugInfos)
9.5.FP9
Problem behoben lt. FixList in der Version