DB2 - Problembeschreibung
| Problem IC78430 | Status: Geschlossen |
DB2 OPTIMIZER CAN CHOOSE A SUB-OPTIMAL PLAN FOR A TABLE THAT HAS A HIGH ROWS-PER-PAGE NUMBER | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / 950 - DB2 | |
| Problembeschreibung: | |
When a table has a high rows-per-page number, DB2 optimizer can be too conservative with the estimate and as a result, prefetching may not occur for a IXSCAN-FETCH operation on such a table, even when the index has a high cluster ratio. This can result in a sub-optimal query plan. | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users. * **************************************************************** * PROBLEM DESCRIPTION: * * See above. * **************************************************************** * RECOMMENDATION: * * Upgrade to version 9.5 Fix Pack 9 or later. * **************************************************************** | |
| Local-Fix: | |
| verfügbare FixPacks: | |
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows | |
| Lösung | |
Problem was first fixed in Version 9.5 Fix Pack 9. | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 31.08.2011 13.03.2012 13.03.2012 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.5.FP9 | |
| Problem behoben lt. FixList in der Version | |
| 9.5.0.9 |
|