DB2 - Problembeschreibung

Problem IC78599 Status: Geschlossen

ERROR IN DB2DIAG.LOG UPON LOW PRIORITY AGENT INTERRUPT IS STILL POSSIBLE
WITH FIX FOR APAR IC73608

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
apar IC73608 fixes a number of scenarios that can lead to 
misleading error messages in the db2diag.log e.g. 
 
2010-12-09-11.48.41.308869+060 E2370E590 LEVEL: Error 
PID : 11041 TID : 46913646016 PROC : 
db2sysc 0 
INSTANCE: db2inst1 NODE : 000 DB : SAMPLE 
APPHDL : 0-51424 APPID: 
*LOCAL.db2inst1.101209104846 
AUTHID : db2inst1 
EDUID : 1751 EDUNAME: db2agent (SAMPLE) 0 
FUNCTION: DB2 UDB, DRDA Application Server, sqljsTermAgentReply, 
 
probe:10 
MESSAGE : DIA5000C A DRDA AS token "AGENT TERMINATING" was 
detected. The 
diagnostic data returned is (SRVDGN): 
"SQLERRP:SQL09054 
SQLCODE:-1224". 
 
However, there were still a few possible scenarios that were not 
fully fixed by that apar.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description.                                       * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 v9.5 fp9 or later.                            * 
****************************************************************
Local-Fix:
none. The message as such is harmless, but it may lead to 
confusion given the high severity level of the message.
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 v9.5 fp9.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC78736 IC84145 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
09.09.2011
12.03.2012
12.03.2012
Problem behoben ab folgender Versionen (IBM BugInfos)
9.5.FP9
Problem behoben lt. FixList in der Version