DB2 - Problembeschreibung

Problem IC80048 Status: Geschlossen

ADD LOGFILE EXTENT NUMBER TO SQLPSUSPENDLOG MESSAGE

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When doing flash copy backups, customers need to know, which is 
the last logfile they need to copy. 
Currently the following message is written to db2diag.log: 
 
2011-11-09-17.54.47.336913+060 I34322068A467 LEVEL: Warning 
PID : 1475 TID : 968 PROC : db2sysc 0 
INSTANCE: db2isp NODE : 000 DB : ISP 
APPHDL : 0-25753 APPID: *LOCAL.db2isp.111109165607 
AUTHID : DB2ISP 
EDUID : 968 EDUNAME: db2agent (ISP) 0 
FUNCTION: DB2 UDB, data protection services, sqlpSuspendLog, 
probe:205 
DATA #1 : <preformatted> 
LSO at suspend time is 8578776072529 
 
As LSOs are not transparent to customers, the log number should 
be added too for serviceability reasons.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 Version 9.7 Fix Pack 6.                       * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 Version 9.7 Fix Pack 6.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC84269 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
29.11.2011
06.06.2012
06.06.2012
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP6
Problem behoben lt. FixList in der Version
9.7.0.6 FixList