DB2 - Problembeschreibung
Problem IC80161 | Status: Geschlossen |
DB2.NET ENTITY PROVIDER FAILS WITH THE CONNECTED SERVER DOESN'T SUPPORT TOP EXPRESSION ERROR. | |
Produkt: | |
DB2 CONNECT / DB2CONNCT / 970 - DB2 | |
Problembeschreibung: | |
After upgrading to DB2 v9.7 FP5 and using the DB2 .NET Entity provider with the Microsoft Visual Studio Entity Framework Modeller - Linq Data Source, and exception can occur as follows: [NotSupportedException: The connected server doesn't support "Top" expression.] IBM.Data.DB2.Entity.SqlGenerator.Visit(DbLimitExpression e) +196 System.Data.Common.CommandTrees.DbLimitExpression.Accept(DbExpre ssionVisitor`1 visitor) +20 IBM.Data.DB2.Entity.SqlGenerator.a(DbExpression A_0, String A_1, TypeUsage A_2, Symbol& A_3) +86 IBM.Data.DB2.Entity.SqlGenerator.Visit(DbProjectExpression e) +162 System.Data.Common.CommandTrees.DbProjectExpression.Accept(DbExp ressionVisitor`1 visitor) +20 IBM.Data.DB2.Entity.SqlGenerator.a(DbExpression A_0, Boolean A_1) +148 IBM.Data.DB2.Entity.SqlGenerator.b(DbExpression A_0) +45 IBM.Data.DB2.Entity.SqlGenerator.a(DbQueryCommandTree A_0, Hashtable& A_1, ArrayList& A_2, String[]& A_3) +491 IBM.Data.DB2.Entity.SqlGenerator.GenerateSql(DbCommandTree tree, DB2ProviderManifest manifest, List`1& parameters, CommandType& commandType, Hashtable& IBM.Data.DB2.Entity.DB2ProviderServices.a(DbProviderManifest A_0, DbCommandTree A_1) +491 IBM.Data.DB2.Entity.DB2ProviderServices.CreateDbCommandDefinitio n(DbProviderManifest manifest, DbCommandTree commandTree) +132 System.Data.Common.DbProviderServices.CreateCommandDefinition(Db CommandTree commandTree) +84 System.Data.EntityClient.EntityCommandDefinition..ctor(DbProvide rFactory storeProviderFactory, DbCommandTree commandTree) +333 | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Windows users using DB2 .NET * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 Version 9.7, Fixpak 6 * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
Lösung | |
First fixed in DB2 Version 9.7, Fixpak 6 | |
Workaround | |
n/a | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC84228 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 02.12.2011 15.06.2012 15.06.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7. | |
Problem behoben lt. FixList in der Version | |
9.7.0.6 |