DB2 - Problembeschreibung
| Problem IC80378 | Status: Geschlossen |
IF THERE IS A BINARY ZERO UTL_FILE WRITES CONTENTS OF THIS STRING ONLY UP TO THE FIRST BINARY ZERO | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
| Problembeschreibung: | |
If there is a binary zero in the string, UTL_FILE writes
contents of this string only up to the first binary zero.
Example:
DECLARE outfile UTL_FILE.FILE_TYPE;
DECLARE col1data varchar(20) for bit data;
CREATE TABLE forbit (col1 varchar(20) for bit data)@
-- 'ABC E' where the 4th byte is null char
INSERT INTO forbit values (x'4142430045')@
-- after the file has been opened/setup:
OPEN testcurs;
FETCH from testcurs into col1data;
CLOSE testcurs;
--stores the column in a variable
SET outfile = UTL_FILE.FOPEN( dirAlias, fileName, 'w' );
CALL UTL_FILE.PUT_LINE( outfile, col1data);
--Now in the file, we only see "ABC", because we stop at null.
However, we should see "ABC^@E" ('^@' represents the null
terminator) | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of UTL_FILE * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 v9.7 FP6 or newer. * **************************************************************** | |
| Local-Fix: | |
| verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
| Lösung | |
First fixed in DB2 v9.7 FP6 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC84255 Nachfolger : | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 12.12.2011 17.12.2012 17.12.2012 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP6 | |
| Problem behoben lt. FixList in der Version | |
| 9.7.0.6 |
|