DB2 - Problembeschreibung
Problem IC80378 | Status: Geschlossen |
IF THERE IS A BINARY ZERO UTL_FILE WRITES CONTENTS OF THIS STRING ONLY UP TO THE FIRST BINARY ZERO | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
If there is a binary zero in the string, UTL_FILE writes contents of this string only up to the first binary zero. Example: DECLARE outfile UTL_FILE.FILE_TYPE; DECLARE col1data varchar(20) for bit data; CREATE TABLE forbit (col1 varchar(20) for bit data)@ -- 'ABC E' where the 4th byte is null char INSERT INTO forbit values (x'4142430045')@ -- after the file has been opened/setup: OPEN testcurs; FETCH from testcurs into col1data; CLOSE testcurs; --stores the column in a variable SET outfile = UTL_FILE.FOPEN( dirAlias, fileName, 'w' ); CALL UTL_FILE.PUT_LINE( outfile, col1data); --Now in the file, we only see "ABC", because we stop at null. However, we should see "ABC^@E" ('^@' represents the null terminator) | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of UTL_FILE * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 v9.7 FP6 or newer. * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
Lösung | |
First fixed in DB2 v9.7 FP6 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC84255 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 12.12.2011 17.12.2012 17.12.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP6 | |
Problem behoben lt. FixList in der Version | |
9.7.0.6 |