DB2 - Problembeschreibung

Problem IC82231 Status: Geschlossen

PIT rollforward for a table space restore appears to be hanging or take
very long time to run.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
PIT rollforward for a table space restore appears to be hanging 
or take very long time to run, there is no identified object the 
RF is waiting for. You might observe this behavior if you issue 
the restore in a heavily loaded and long running system.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Any DB2 v970 lower that FixPack 7                            * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Install/upgrade to DB2 v970 Fix Pack 7                       * 
****************************************************************
Local-Fix:
Force off long connected session and in some situation you might 
need to force off all or leave the roll forward to run and it 
will eventually finish.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC88331 
Nachfolger : 