DB2 - Problembeschreibung
Problem IC83532 | Status: Geschlossen |
SIGNAL #11 SIGSEGV CRASH CALLING CONVERTTO64BIT FROM SNAPSHOT_LOCK | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
When calling SYSPROC.SNAPSHOT_LOCK the db2fmp process used to run non-SQL stored procedures and user defined functions may abnormally terminate with a segmentation fault or signal #11 with the following stack: ossDumpStackTraceEx OSSTrapFile6dumpExEmiP7siginfoPvm OSSTrapFile4dumpEmiP7siginfoPv sqlo_trce sqlo_dari_trca offset in lib: 0x000000000000EB10 ; convertTo64bitP16sqlm_header_dataPlPs snapshot_lock sqloInvokeFnArgs offset in lib: 0x0000000000AE1086 ; sqlerDyload sqlerFmpListener main | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of Lock Snapshots * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 9.7 FP7 * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows | |
Lösung | |
Problem first fixed in DB2 9.7 FP7 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 16.05.2012 08.04.2013 08.04.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP7 | |
Problem behoben lt. FixList in der Version | |
9.7.0.7 |