DB2 - Problembeschreibung
| Problem IC85738 | Status: Geschlossen |
SLOW ETHERNET FAILOVER OF PRIMARY CF ROLE | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
| Problembeschreibung: | |
If an ethernet failure occurs, the primary CF role will take a long time to failover. It can take up to 2 minutes from the time of failure until the primary CF role is restarted. | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 PureScale users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 V10.1 FP1 * **************************************************************** | |
| Local-Fix: | |
Set the tcp_keepinit value on the CF host to 10 seconds (from the default 75 seconds) | |
| verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 1 for Linux, UNIX, and Windows | |
| Lösung | |
The fix will be included in DB2 V10.1 FP1 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 04.08.2012 07.11.2012 07.11.2012 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
| Problem behoben lt. FixList in der Version | |
| 10.1.0.1 |
|
| 10.5.0.1 |
|