Problem IC86943 Status: Geschlossen

PRECISION PROBLEM WHEN CONVERTING A DOUBLE TO A DECIMAL.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
APAR IC73485 provided an alternate floating point to decimal 
conversion that took a truncation approach instead of rounding. 
A problem has been identified in that alternate approach that 
gives an imprecise conversion. This defect will further correct 
this truncation approach to give a more precise conversion.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 Version 9.7 Fix Pack 8.                       * 
****************************************************************
Local-Fix:
Please contact DB2 support team, who can provide guidance on how 
to enable this alternate mode for converting floating point 
types to DECIMAL.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 Version 9.7 Fix Pack 8.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC89710 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
02.10.2012
03.04.2013
03.04.2013
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP8
Problem behoben lt. FixList in der Version
9.7.0.8 FixList