DB2 - Problembeschreibung
| Problem IC87891 | Status: Geschlossen |
XA AES CONNECTION TO DB2 Z/OS SERVER GETS SQL30082N RC=17 | |
| Produkt: | |
DB2 CONNECT / DB2CONNCT / A10 - DB2 | |
| Problembeschreibung: | |
XA connection against DB2 z/os v9.1 CM mode server with Advanced Encrpytion (AES) fail with. SQL30082N rc=17. The issue can happen when client forces reconnect through Syncpoint manager ( SPM). Impacted release:v9.7.4,v9.7.5,v9.7.6 DB2 Connect Server | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 Connect Server * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to v10.1.2 or higher fixpack. * **************************************************************** | |
| Local-Fix: | |
catalogging tcpip loop back or setting registry variable DB2CONNECT_IN_APP_PROCESS=NO (then restart instance) | |
| verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 2 for Linux, UNIX, and Windows | |
| Lösung | |
Upgrade to v10.1.2 or higher fixpack. | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 04.11.2012 02.01.2013 02.01.2013 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
| Problem behoben lt. FixList in der Version | |
| 10.1.0.2 |
|
| 10.5.0.2 |
|