Problem IC89652 Status: Geschlossen

.NET APPLICATION MAY HANG AFTER RECEIVING COMMUNICATION ERROR

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
.NET application may hang after receiving communication error. 
 
In trace you can see even after connection failure, DB2 calls 
being executed which will result in hang situation like this: 
 
1125836 | | | | | | DB2DataReader.Dispose entry 
1125837 | | | | | | | DB2DataReader.Dispose entry 
1125838 | | | | | | | DB2DataReader.Dispose data [probe 15] 
1125839 | | | | | | | | SQLFreeStmt entry 
1125840 | | | | | | | | | sqloxltc_app entry 
1125841 | | | | | | | | | | sqlo_xlatch::getConflict entry 
 
SQLFreeStmt is being called but never exited.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 V9.7 FP8                                      * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 V9.7 FP8
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC91777 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
18.01.2013
26.06.2013
26.06.2013
Problem behoben ab folgender Versionen (IBM BugInfos)