DB2 - Problembeschreibung
| Problem IC91288 | Status: Geschlossen |
DEADLOCK CAN BE HAPPEN BETWEEN THE IBM INFORMIX CSDK ODBC DRIVER AND THE IBM DB2 DATASERVER DRIVER WHEN USED IN THE SAME APP | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
| Problembeschreibung: | |
Deadlock can occur on Windows because both drivers make a system call to getenv() which locks a critical section. If the timing is perfect this can cause a deadlock. Possible workaround to minimize the impact is to modify the CriticalSectionTimeout: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\CriticalSectionTimeout | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Windows Only * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Problem was first fixed in Version 10.1 Fix Pack 3 * **************************************************************** | |
| Local-Fix: | |
| verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 3 for Linux, UNIX, and Windows | |
| Lösung | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 03.04.2013 01.10.2013 01.10.2013 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
| Problem behoben lt. FixList in der Version | |
| 10.1.0.3 |
|
| 10.1.0.3 |
|