DB2 - Problembeschreibung
Problem IC91610 | Status: Geschlossen |
LOAD MIGHT FAIL WITH SQL1188N ERROR WHEN THERE ARE MULTIPLE CUR SORS DECLARED WHOSE NAMES MATCH IN FIRST 'N' CHARACTERS (N IS TH | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
When we perform more than one load, and when first load with a cursor is successful, second load with a different cursor whose name partially matches the first cursor and upto the length of second cursor name, load might fail with SQL1188N error. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 CLP Load users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to v97fp9 or later releases. * **************************************************************** | |
Local-Fix: | |
Use entirely different cursor names for load | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows | |
Lösung | |
Problem fixed in db2_v97fp9 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC93692 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 16.04.2013 17.12.2013 17.12.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP9 | |
Problem behoben lt. FixList in der Version | |
9.7.0.9 | |
9.7.0.9 |