DB2 - Problembeschreibung
Problem IC93975 | Status: Geschlossen |
CLIENT REROURE FAILS TO ZOS SERVER WITH ERRONEOUS MESSAGE "ENSURE APAR PM24292 IS INSTALLED ON THAT SYSTEM." | |
Produkt: | |
DB2 CONNECT / DB2CONNCT / 970 - DB2 | |
Problembeschreibung: | |
Client reroute error can occur if gateway reconnects to recover from stale outbound connection. You can see following erroneous messages in the db2diag.log on the gateway: 2013-04-24-11.41.04.020857-240 I85377A796 LEVEL: Error PID : 10879056 TID : 18763 PROC : db2sysc INSTANCE: ddcsenv NODE : 000 DB : LOCDB2E APPHDL : 0-46095 EDUID : 18763 EDUNAME: db2agentg (LOCDB2E ) FUNCTION: DB2 UDB, DRDA Application Requester, sqljrParseMgrLvls, probe:489 MESSAGE : Downlevel member cannot be used for transaction-level workload balancing or automatic client reroute. If you are accessing a DB2 for z/OS sysplex, ensure APAR PM24292 is installed on that system. DATA #1 : Hex integer, 2 bytes 0x2407 DATA #2 : String with size, 8 bytes DSN09015 DATA #3 : unsigned integer, 2 bytes 10 DATA #4 : String with size, 21 bytes DSN09015............. DATA #5 : unsigned integer, 2 bytes 8 2013-04-24-11.41.04.021407-240 I86174A465 LEVEL: Warning PID : 10879056 TID : 18763 PROC : db2sysc INSTANCE: ddcsenv NODE : 000 DB : LOCDB2E APPHDL : 0-46095 EDUID : 18763 EDUNAME: db2agentg (LOCDB2E ) FUNCTION: DB2 UDB, DRDA Application Requester, sqljrDrdaArShouldDoCR, probe:998 MESSAGE : ZRC=0x8037006D=-2143879059=SQLJR_CABLT "CA BUILT" DATA #1 : String, 22 bytes Client Reroute failed. Client application might report SQL1224N. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to fp9 or above * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows | |
Lösung | |
First fixed in v9.7fp9 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC94088 IC95461 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 08.07.2013 23.12.2013 23.12.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP9 | |
Problem behoben lt. FixList in der Version | |
9.7.0.9 | |
9.7.0.9 |