DB2 - Problembeschreibung
Problem IC95195 | Status: Geschlossen |
DURING RESTART OF THE SERVER, DB2FMCD PROCESS CAN REPORT MESSAGE THERE IS ALREADY A COPY OF FAULT MONITOR DAEMON PROCESS RUNNING | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
When the db2 fault monitor is configured to start on system reboot. After a reboot the following message can be seen in the db2diag.log. 2013-03-20-09.37.47.625422-600 I9088E1002 LEVEL: Error PID : 3260 TID : 140154682197792PROC : db2fm INSTANCE: db2inst1 NODE : 000 FUNCTION: DB2 Common, Generic Control Facility, gcf_start, probe:40 MESSAGE : ECF=0x90000361=-1879047327=ECF_FM_DB2FMD_PROCESS_EXIST There is already a copy of fault monitor daemon process running CALLSTCK: (Static functions may not be resolved correctly, as they are resolved to the nearest symbol) [0] 0x00007F784F6F873B pdOSSeLoggingCallback + 0x265 [1] 0x00007F7851894206 /opt/ibm/db2/V9.7/lib64/libdb2osse.so.1+ 0x1D8206 [2] 0x00007F7851895A50 ossLog + 0xD4 [3] 0x00007F784B5EC6D0 gcf_start + 0x286 [4] 0x00007F7851272DBB _ZN9GcfCaller5startEP12GCF_PartInfomP11GCF_RetInfo + 0x1B9 [5] 0x0000000000405765 main + 0x14FD [6] 0x000000315621ECDD __libc_start_main + 0xFD [7] 0x00000000004041D9 __gxx_personality_v0 + 0x151 [8] 0x0000000000000000 ?unknown + 0x0 [9] 0x0000000000000000 ?unknown + 0x0 | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 Version 9.7 Fix Pack 9 or Later. * **************************************************************** | |
Local-Fix: | |
Manually verify that the db2fmd process is running for the instance. If it is then this error log can be safely ignored. | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows | |
Lösung | |
First Fixed in DB2 V9.7 Fix Pack 9 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC96533 IC96697 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 26.08.2013 23.12.2013 23.12.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP9 | |
Problem behoben lt. FixList in der Version | |
9.7.0.9 | |
9.7.0.9 |