DB2 - Problembeschreibung
| Problem IC95368 | Status: Geschlossen |
THE UNINSTALLER OF 64-BIT DATA SERVER CLIENT/DRIVER DOESN'T REMOVE 32BIT ODBC DATA SOURCES. | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / A50 - DB2 | |
| Problembeschreibung: | |
Under 64-bit Windows OS uninstallation process leaves 32-bit ODBC data source created by the client/driver. The problem doesn't apply to 64-bit ODBC data sources. Local fix is to manually delete a leftover registry keys. | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All DB2 V10.5 on LUW users. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to DB2 V10.5 Fix Pack 3 or higher. * **************************************************************** | |
| Local-Fix: | |
Manually delete a leftover registry keys. The default location is: HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ODBC\ODBC.INI. | |
| verfügbare FixPacks: | |
DB2 Version 10.5 Fix Pack 3 for Linux, UNIX, and Windows | |
| Lösung | |
Problem Fixed In DB2 V10.5 Fix Pack 3 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 27.08.2013 07.04.2014 07.04.2014 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
| Problem behoben lt. FixList in der Version | |
| 10.5.0.3 |
|
| 10.5.0.3 |
|