DB2 - Problembeschreibung
Problem IC99060 | Status: Geschlossen |
POSSIBLE ABEND OF DB2PCLNR DUE TO SIGSEGV IN SQLBCLNRCONDLATCHPAGE OR SQLBCLNRGATHERFORTHRESH | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
Under rare timing conditions, DB2 engine (EDU db2pclnr) might abend with SIGSEGV in the following stack: AIX: sqlbClnrCondLatchPage sqloDispatchNBlocks or sqlbClnrCondLatchPage sqlbClnrDispatchSomeAIO or sqlbClnrCondLatchPage Other platforms: sqlbClnrGatherForThresh sqlbClnrGatherPages sqlbClnrEntryPoint sqbPgClnrEdu::RunEDU | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 version 9.7 Fix Pack 10 or higher. * **************************************************************** | |
Local-Fix: | |
Enable alternative page cleaning: db2set DB2_USE_ALTERNATE_PAGE_CLEANING=ON | |
Lösung | |
Fixed in DB2 version 9.7 Fix Pack 10. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC99216 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 29.01.2014 09.12.2014 09.12.2014 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP10 | |
Problem behoben lt. FixList in der Version | |
9.7.0.10 |