Informix - Problembeschreibung
Problem IT01006 | Status: Geschlossen |
UNINITIALIZED VALUE_T IN INSONE_NEXT CAN CAUSE ASSERTION FAILURE AFTER UNEXPECTED CALL TO EXECUTE_BLOB_ASSIGN | |
Produkt: | |
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50 | |
Problembeschreibung: | |
This problem was reported in 11.50.FC5WM5 on linux x86_64 but I've also confirmed the same problem resides in 12.10.FC2 A sample stack from a failure looks like: (/usr/informix_engine/bin/oninit) afstack (/usr/informix_engine/bin/oninit) mt_ex_throw_sig (/usr/informix_engine/bin/oninit) afsig_handler (Linux) <signal frame> (/usr/informix_engine/bin/oninit) fm_openany (/usr/informix_engine/bin/oninit) fmbcreate (/usr/informix_engine/bin/oninit) scollasblob (/usr/informix_engine/bin/oninit) execute_blob_assign (/usr/informix_engine/bin/oninit) insone_next (/usr/informix_engine/bin/oninit) doinsert (/usr/informix_engine/bin/oninit) excommand (/usr/informix_engine/bin/oninit) sq_execute (/usr/informix_engine/bin/oninit) sqmain (/usr/informix_engine/bin/oninit) spawn_thread (/usr/informix_engine/bin/oninit) startup | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users running insert statements with NULL values * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-11.50.xC10 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem Fixed In IDS-11.50.xC10 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 11.04.2014 16.10.2015 16.10.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
12.10.xC4.W1 |
![]() |
12.10.xC5 |
![]() |
12.10.xC5.W1 |
![]() |