Informix - Problembeschreibung
| Problem IT02702 | Status: Geschlossen |
A SELECT STATEMENT FROM A VIEW WITH A SUBSELECT RETURNS ERROR -392 | |
| Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
| Problembeschreibung: | |
Running a select against a view that has a correlated subquery
and IFX_FOLDVIEW is enabled (default), might fail with error
-392
392: System error - unexpected null pointer encountered.
Error in line 1
Near character position 52
With a trap enabled for error -392, the following stack is
observed:
11:07:30 Stack for thread: 3037 sqlexec
oninit :: afstack
oninit :: afhandler
oninit :: affail_interface
oninit :: check_traperror
oninit :: sqerr
oninit :: opcsqp
oninit :: op_opinit
oninit :: sqoptim
oninit :: bldstructs
oninit :: sqcmd
oninit :: sq_cmnd
oninit :: sq_prepare
oninit :: sqmain
oninit :: listen_verify
oninit :: spawn_thread
oninit :: th_init_initgls
oninit :: startup | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-12.10.xC5 * **************************************************************** | |
| Local-Fix: | |
If you disable IFX_FOLDVIEW so the view cannot be folded / merged into the optimized query or you remove the views subquery, the select runs successfully. | |
| Lösung | |
Problem Fixed In IDS-12.10.xC5 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 20.06.2014 16.10.2015 16.10.2015 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
| Problem behoben lt. FixList in der Version | |
| 12.10.xC4.W1 |
|
| 12.10.xC5 |
|
| 12.10.xC5.W1 |
|