home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Neueste VersionenFixList
15.0.xC1.2 FixList
14.10.xC13.3 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

Informix - Problembeschreibung

Problem IT02953 Status: Geschlossen

ONBAR ABENDS IN BSAGETENVIRONMENT CALL USING EMC NETWORKER STORAGE MANAGER

Produkt:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problembeschreibung:
Onbar using EMC NetWorker storage manager can abort immediately 
after connecting to storage manager. 
A dependency on BAR_DEBUG setting has been observed, but this is 
deemed purely accidental. 
 
bar_act.log might contain: 
 2014-06-23 09:56:57 9650  9644 Using EMC's NetWorker XBSA 
version 1.0 as the Storage Manager. XBSA API version is 1.0.1. 
 2014-06-23 09:56:57 9650  9644 Working with networker xbsa as 
generic storage manager. 
 2014-06-23 09:56:58 9650  9644 Successfully connected to 
Storage Manager. 
 2014-06-23 09:56:58* 9650  9644 ASSERT: file bar_unix.c line 
1316 - contact product support 
 
No meaningful bar_debug output could be obtained as setting 
BAR_DEBUG to anything higher than 1 would have avoided the 
problem. 
 
Closer inspection showed the crash is occurring in an initial 
call to BSAGetEnvironment() XBSA function.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Users using onbar with storage managers other than TSM and   * 
* PSM.                                                         * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.xC5                      * 
****************************************************************
Local-Fix:
An easy workaround is setting IFX_BAR_NO_LONG_BUFFERS 
environment variable.
Lösung
Problem Fixed In IBM Informix Server 12.10.xC5
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
03.07.2014
19.01.2016
19.01.2016
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC5
Problem behoben lt. FixList in der Version
12.10.xC5 FixList
12.10.xC5.W1 FixList