Informix - Problembeschreibung

Problem IT03431 Status: Geschlossen

-392 RESULTS FROM COMPLEX ANSI JOIN QUERY WITH UNION ALL VIEW AND A SECOND
VIEW WITH GROUP BY AND AGGREGATION

Produkt:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problembeschreibung:
The error   "392: SYSTEM ERROR - UNEXPECTED NULL POINTER 
ENCOUNTERED." may occur  on 12.10.FC3XB and 12.10.FC3XE. 
 
A UNION ALL view folding enhancement was included in these 
releases. 
As a result of this enhancement, the UNION ALL gets folded but 
the other part of the view is improperly materialized when there 
is a group by and aggregation in the view definition. This was 
fixed by APAR IT03042. Subsequently it was discovered that when 
the STMT_CACHE is set to 2 in onconfig, the -392 error occurs 
again.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Users of 12.10.xC4.                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* A query may return -392 error under the following            * 
* conditions:                                                  * 
*   - statement cache is turned on in the ONCONFIG file        * 
* (STMT_CACHE 2)                                               * 
*   - query contains two derived tables, DT1, DT2              * 
*   - DT1 contains a UNION ALL and does not contain any group  * 
* by, order by or aggregates                                   * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IDS-12.10.xC5                                      * 
****************************************************************
Local-Fix:
Lösung
Problem Fixed In IDS-12.10.xC5
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
28.07.2014
16.10.2015
16.10.2015
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
12.10.xC4.W1 FixList
12.10.xC5 FixList
12.10.xC5.W1 FixList