Informix - Problembeschreibung
Problem IT03458 | Status: Geschlossen |
ERROR -768 IN ROUTINE PULL_RANGE POSSIBLE FOR QUERY WITH SEVERAL JOINS WHEN MULTI_INDEX SCAN IS USED | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
A query with several joins might return error -768 when the optimizer chooses a multi-index scan: 768: Internal error in routine pull_range: sort pages not available. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-12.10.xC5 * **************************************************************** | |
Local-Fix: | |
As a workaround, consider disabling multi-index scans using undocumented configuration parameter 'MULTI_INDEX_SCAN 0'. | |
Lösung | |
Problem Fixed In IDS-12.10.xC5 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 29.07.2014 16.10.2015 16.10.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
12.10.xC5 |
![]() |
12.10.xC5.W1 |
![]() |