Problem IT03728 Status: Geschlossen

MAX_COORDAGENTS CANNOT BE SET TO 0 VALUE

Produkt:
DB2 FOR LUW / DB2FORLUW / A50 - DB2
Problembeschreibung:
When we activate the database, the DB2 system need to start up 
couples  of system applications. 
 
 If MAX_COORDAGENTS is set to 0,the database will not able to 
activate  and it will hung. The code 
 
 that automatically  adjust the MAX_COORDAGENTS will not able to 
execute  because the database 
 
 system  have not come  up and running. 
 
 
 
 Hence  we  should not allow  this MAX_COORDAGENTS to set to 0 
and it  should throw an error in 
 
 case  it is tried to be set to  0 via some user or any defect 
inadvertently. 
 
 However due to  APAR   IC97753   is  inadvertently set to 
0,which  made the DB unusable and hung state.
Problem-Zusammenfassung:
If MAX_COORDAGENTS is set to 0,the database will not able to 
activate  and it will hung.
Local-Fix:
db2  update  dbm  cfg  using  MAX_CORDAGENTS  to any non zero 
value.
Lösung
Workaround
db2  update  dbm  cfg  using  MAX_CORDAGENTS  to any non zero 
value.
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
12.08.2014
04.12.2014
04.12.2014
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
10.5.0.5 FixList