home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Neueste VersionenFixList
14.10.xC11 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

Informix - Problembeschreibung

Problem IT04416 Status: Geschlossen

INFORMATION REGARDING THE MAXIMUM VALUE OF TAPESIZE PARAMETER IS NOT THE
SAME IN ALL THE INFORMIX DOCUMENTATION

Produkt:
INFORMIX SERVER / 5725A3900 / B50 - IDS 11.50
Problembeschreibung:
The information in the "TAPESIZE configuration parameter" link 
of infocenter for IDS 11.50, 11.70 and 12.10 shows : 
 
TAPESIZE configuration parameter 
 
Use the TAPESIZE parameter specifies the size of the device to 
which ontape backs up storage spaces. 
 
onconfig.std value 
    0 
units 
    Kilobytes 
range of values 
    0 or any positive number. The real value operating system 
dependent. 
 
we can see the above information in the following links : 
 
http://www-01.ibm.com/support/knowledgecenter/SSGU8G_11.50.0/com 
.ibm.adref.doc/ids_adr_0179.htm?lang=en 
 
http://www-01.ibm.com/support/knowledgecenter/SSGU8G_11.70.0/com 
.ibm.bar.doc/ids_bar_525.htm?lang=en 
 
http://www-01.ibm.com/support/knowledgecenter/SSGU8G_12.1.0/com. 
ibm.bar.doc/ids_bar_525.htm?lang=en 
 
 
However in the information to "Specify the tape size" we have 
that the range to configure TAPESIZE is from 0 to 2,097,151. 
 
Use the TAPESIZE and LTAPESIZE configuration parameter 
parameters to specify the maximum amount of data that you can 
write to a tape. 
 
To write or read the tape to the end of the device, set TAPESIZE 
and LTAPESIZE to 0. You cannot use this option for remote 
devices. 
 
When you specify the tape device as /dev/null, the corresponding 
tape size is ignored. 
 
The range of values for these parameters is 0 - 2,097,151. 
 
we can see the above information in the following links : 
 
http://www-01.ibm.com/support/knowledgecenter/SSGU8G_11.50.0/com 
.ibm.bar.doc/ids_bar_301.htm?lang=en 
 
http://www-01.ibm.com/support/knowledgecenter/SSGU8G_11.70.0/com 
.ibm.bar.doc/ids_bar_301.htm 
 
http://www-01.ibm.com/support/knowledgecenter/SSGU8G_12.1.0/com. 
ibm.bar.doc/ids_bar_301.htm 
 
Per development the correct value is 0 to 2,097,151, it is not 0 
to any positive number.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Informix 11.50, 11.70, 12.10                                 * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* See Problem Conclusion                                       * 
****************************************************************
Local-Fix:
Lösung
The range of values for the TAPESIZE and LTAPESIZE configuration 
parameters is 0 - 4294967296 (4 TB).
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
16.09.2014
16.10.2015
16.10.2015
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
12.10.xC5 FixList
12.10.xC5.W1 FixList