DB2 - Problembeschreibung

Problem IT04550 Status: Geschlossen

APP HANG MAY OCCUR FOR CLOB COLUMNS WHEN FULLYMATERIALIZELOBDATA IS FALSE
AND PROGRESSIVESTREAMING IS 2.

Produkt:
DB2 DATA SRVR D / DB2DSDRVR / A50 - DB2
Problembeschreibung:
Type-4 connectivity: Application may hang when trying to 
retrieve a CLOB column when the JCC property 
fullyMaterializeLobData is set to false and the 
progressiveStreaming property is set to 2 or  disabled.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users of IBM Data Server Driver for JDBC and SQLJ        * 
* shipped with DB2 10.5 releases earlier than DB 10.5 Fixpack  * 
* 4.                                                           * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* Refer Error Description.                                     * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 10.5 Fixpack 4                                * 
****************************************************************
Local-Fix:
enable Progressive streaming by setting progressiveStreaming=1
Lösung
Upgrade to DB2 10.5 Fixpack 4
Workaround
keiner bekannt / siehe Local-Fix