DB2 - Problembeschreibung

Problem IT05278 Status: Geschlossen

XI/NOTIFY RESET USES CONNECTION ON DOWN PORT

Produkt:
DB2 FOR LUW / DB2FORLUW / A10 - DB2
Problembeschreibung:
If a port on an RDMA card becomes unavailable (for example, a 
cable is removed), pureScale can potentially attempt to reuse 
connections established through that port. These connections are 
no longer valid, but each attempted use will result in a 15 
second timeout before the connection is torn down, and a 
different connection in the cache is attempted. 
 
This apar fix will first check the status of the port before 
using a connection.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* See Error Description                                        * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to V10.1 FP5 for this APAR fix.                      * 
****************************************************************
Local-Fix:
Lösung
See Error Description
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
30.10.2014
13.08.2015
13.08.2015
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
10.1.0.5 FixList