Informix - Problembeschreibung
Problem IT05848 | Status: Geschlossen |
AFTER YOU SELECT FROM SYSMACHINEINFO INTO ANOTHER TABLE, YOU MIG HT GET ERROR -1284 OR GARBAGE RESULTS SELECTING FROM THAT TABLE | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
The sysmaster database contains many tables that you can use to monitor your system. Among those tables is sysmachineinfo, which contains columns of OS related information. However, on Windows, if you select from that table into a target table (like it is usually done when creating scheduler sensors), you might get error -1284 or garbage results when selecting from that target table. So far this has been observed for the contents of columns os_semnumperid and os_semops. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All Windows server users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC5 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC5 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 01.12.2014 16.10.2015 16.10.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC5 | |
Problem behoben lt. FixList in der Version | |
12.10.xC5 |
![]() |