Informix - Problembeschreibung
| Problem IT06589 | Status: Geschlossen |
MIGRATION FROM 12.10.FC3 TO 12.10.FC4W1 COULD LEAD TO -9793 USER DEFINED ROUTINE (UPDATE) MODULE LOAD FAILED | |
| Produkt: | |
IFMX ULT WHSE E / IM0019BOS / C10 - IDS 12.10 | |
| Problembeschreibung: | |
After a migration from 12.10.FC3 to 12.10.FC4W1 a
PutElemNoDups() fails with -9793 User Defined Routine (update)
module load failed.
Message in the online.log
10:18:22 Loading Module
<$INFORMIXDIR/extend/TimeSeries.6.00.FC3/TimeSeries.bld>
10:18:22 (2): The C Language Module
<$INFORMIXDIR/extend/TimeSeries.6.00.FC3/TimeSeries.bld> can't
load
reason: Cannot access library file | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * 12.10.xC4, 12.10.xC4W1, 12.10.xC4w2, 12.10.xC5 * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
| Local-Fix: | |
| Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 19.01.2015 30.12.2015 30.12.2015 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC6 | |
| Problem behoben lt. FixList in der Version | |
| 12.10.xC5.W1 |
|
| 12.10.xC6 |
|