Informix - Problembeschreibung
Problem IT06735 | Status: Geschlossen |
ONPSM DOES NOT WORK WITH EFFECTIVE GROUP ID SET TO BARGROUP - RETURNING -88300 | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
onpsm does not work with effective group id set to "bargroup". While onbar works with effective group id set to "bargroup", onpsm returns: Error -88300: The current user does not have authorization to run this utility. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Informix 12.10 * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * See Problem Conclusion. * **************************************************************** | |
Local-Fix: | |
Lösung | |
To run the onpsm utility, you must be user root or informix. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 26.01.2015 16.10.2015 16.10.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
12.10.xC5 |
![]() |