DB2 - Problembeschreibung
| Problem IT07231 | Status: Geschlossen |
APPLICATIONS MONITORED FOR EI CAN RESULT IN MEMORY DIAGNOSTICS ERROR IF AN ERRONEOUS QUERY LONGER THAN 512 CHARACTERS IS ISSUE | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / A50 - DB2 | |
| Problembeschreibung: | |
The problem happens when running a erroneous query longer than 512 character because of which we call the CLI_cscSetKeylessServerStatement function where the memory problem happens. Problem encountered on Linux 390 10.5 fp4 | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 10.5 Fixpack 7 * **************************************************************** | |
| Local-Fix: | |
| Lösung | |
First fixed in DB2 10.5 Fixpack 7 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 18.02.2015 05.02.2016 05.02.2016 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
| Problem behoben lt. FixList in der Version | |
| 10.5.0.7 |
|