Informix - Problembeschreibung
Problem IT07261 | Status: Geschlossen |
IT IS POSSIBLE TO HAVE INCORRECT FAILURE REASON PRINTED IF INFORMIX ASSERT FAILS IN ROWALTER() FUNCTION | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
It is possible to have incorrect Assert Failure message printed in online.log if Informix fails in rowalter() function. For example, this is the message printed in the log file (incorrect): Assert Failed: ustat_1901 This is the accompanying stack: afstack afhandler affail_interface rowalter rsseqscan_read fmseqscan_read readseq_batch gettupl scan_next join_next join_next getrow fetchrow exfetch sql_nfetch sq_nfetch sqmain spawn_thread th_init_initgls startup | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All IDS users who encounter a failure when reading an old * * row from a table that has been altered in-place. The error * * message used by support to diagnose the problem may be * * incorrect. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC5 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC5 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 19.02.2015 16.10.2015 16.10.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC5 | |
Problem behoben lt. FixList in der Version | |
12.10.xC5 |
![]() |
12.10.xC5.W1 |
![]() |