Problem IT07336 Status: Geschlossen

TRUNCATE TABLE WHILE CLIENTS CONTINUALLY INSERT CAN CAUSE ASSERTION FAILURE

Produkt:
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50
Problembeschreibung:
This problem was originally seen on AIX 11.50.FC5WM5.  It also 
reproduced the failure on AIX 12.10.FC4W1. 
 
An example of the assertion failure: 
 
   15:56:38  IBM Informix Dynamic Server Version 12.10.FC4W1 
Software Serial Number AAA#B000000 
   15:56:38  Assert Failed: No Exception Handler 
   15:56:38   Who: Session(1104, informix@host456, 55116558, 
700000010490038) 
                   Thread(1133, sqlexec, 70000001044f548, 8) 
                   File: mtex.c Line: 508 
   15:56:38   Results: Exception Caught. Type: MT_EX_OS, 
Context: mem 
   15:56:38   Action: Please notify IBM Informix Techical 
Support. 
   15:56:38   See Also: /tmp/af.855a214 
 
(oninit)afstack 
(oninit)mt_ex_throw_sig@AF11_4 
(oninit)afsig_handler 
(oninit)closerel 
(oninit)closerel 
(oninit)common_bbind 
(oninit)sq_bbind 
(oninit)sqmain 
(oninit)listen_verify 
(oninit)spawn_thread 
(oninit)th_init_initgls 
(oninit)startup
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* When a statement containing blobs is reprepared.             * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to 12.10.xC6 or earlier PID if available.            * 
****************************************************************
Local-Fix:
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
24.02.2015
30.12.2015
30.12.2015
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC6
Problem behoben lt. FixList in der Version
12.10.xC6 FixList