Informix - Problembeschreibung
Problem IT07599 | Status: Geschlossen |
DR_PRPING THREAD MAY BECOME STUCK IN RUNNING STATE FOLLOWING HDR CONNECTION FAILURE | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
The dr_ping thread may become stuck in a continuously running state following a connection failure with the HDR secondary server. The stack for this thread will be similar to the following: mt_spin_lock_wait() asf_checkexp() sqscb_cleanup() destroy_session() dr_primary_ping() startup() In addition the command onstat -g ath will show the dr_prsend thread waiting on the dr_prping thread, for example: ifx$ onstat -g ath | grep dr_ 202 7000000501f80d0 700000020423e68 1 join wait 1116 10cpu dr_prsend 1116 700000050741028 700000020429cf0 1 running 10cpu dr_prping Once in this state the HDR connection cannot be re-established until the primary server is restarted. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Informix users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 09.03.2015 30.12.2015 30.12.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC6 | |
Problem behoben lt. FixList in der Version | |
12.10.xC5.W1 |
![]() |