Informix - Problembeschreibung
| Problem IT08441 | Status: Geschlossen |
LOCKING TEMPORARY TABLE CAUSES HDR PRIMARY TO CRASH | |
| Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
| Problembeschreibung: | |
Locking a temporary table in exclusive mode causes HDR primary
to crash.
12:02:16 Assert Failed: No Exception Handler
12:02:16 IBM Informix Dynamic Server Version 12.10.FC5
12:02:16 Who: Session(69, informix@server, 12053, 0x44c36d78)
Thread(98, sqlexec, 44bf80a8, 1)
File: mtex.c Line: 508
12:02:16 Results: Exception Caught. Type: MT_EX_OS, Context:
mem
12:02:16 Action: Please notify IBM Informix Techical Support.
12:02:16 See Also: /usr/informix/tmp/af.44a3118
12:02:17 Thread ID 98 will now be suspended.
(oninit) afstack
(oninit) mt_ex_throw_sig
(oninit) afsig_handler
(Linux) <signal frame>
(/lib64/libc-2.5.so) __GI_strcpy
(oninit) cloneLogTableLock
(oninit) dolock_int
(oninit) aud_dolock
(oninit) excommand
(oninit) sq_execute
(oninit) sqmain
(oninit) spawn_thread
(oninit) th_init_initgls
(oninit) startup | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of HDR, RSS and SDS clusters. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
| Local-Fix: | |
| Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 21.04.2015 30.12.2015 30.12.2015 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC6 | |
| Problem behoben lt. FixList in der Version | |
| 12.10.xC6 |
|