Informix - Problembeschreibung

Problem IT09585 Status: Geschlossen

IWA: LOAD OF DATA MART CAN FAIL WITH ERROR AQT10205I WHEN VIEW REFERS TO
MORE THAN ONE SERIAL COLUMN

Produkt:
INFORMIX WHSE A / 5725D1400 / C10 - IDS 12.10
Problembeschreibung:
You can observe an error 
 
(U0001) - severe: AQT10205I:  An internal processing error 
occurred in the stored procedure. Diagnostic information: An 
assertion 'false' failed. Additional info: unloading data 
failed, check 
/tmp/iwaunld.7605e19c-3eb3-4297-8513-4638252ca3ad.out 
Error in line 1 
 
when attempting to load a data mart into the Informix Warehouse 
Accelerator. 
 
This can happen when one of the loaded objects is a view which 
refers to more than one SERIAL/SERIAL8/BIGSERIAL column. 
 
The error in the *.out file is pointing to this: 
 
create external table ... 
; 
  362: Can have only one column of serial/(serial8 or bigserial) 
type. 
 
As a temporary relief you can change the view by casting the 
offending columns to an appropriate non-SERIAL type or, when the 
columns are not supposed to be processed by excluding those 
columns.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* IWA users with data mart containing a view that has multiple * 
* serial columns (from multiple base tables) get error for     * 
* loadMart.                                                    * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.xC6.                     * 
****************************************************************
Local-Fix:
Lösung
Problem Fixed In IBM Informix Server 12.10.xC6.
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
22.06.2015
30.12.2015
30.12.2015
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC6
Problem behoben lt. FixList in der Version
12.10.xC6 FixList