Informix - Problembeschreibung
| Problem IT10728 | Status: Geschlossen | 
MAIN_LOOP ABENDING IN NEED_TO_CKPT() WITH AUTO_CKPTS ON AND RAS_PLOG_SPEED VERY LOW  | |
| Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10  | |
| Problembeschreibung: | |
An 'fpe' floating-point-exception (or EXCEPTION_INT_DIVIDE_BY_ZERO on Windows) can occur in main_loop thread doing need_to_ckpt() shortly after engine fast recovery if using RTO_SERVER_RESTART, AUTO_CKPTS is On, RAS_LLOG_SPEED is 0 and RAS_PLOG_SPEED non-zero, but below 8. An engine configured this way will not be able to stay up for more than a few seconds after fast recovery completed.  | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * informix customers * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * ****************************************************************  | |
| Local-Fix: | |
Increase onconfig RAS_PLOG_SPEED to >= 8 or set to 0.  | |
| Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC6  | |
| Workaround | |
keiner bekannt / siehe Local-Fix  | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung:  | 17.08.2015 30.12.2015 30.12.2015  | 
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC6  | |
| Problem behoben lt. FixList in der Version | |
| 12.10.xC6 | 
 |