Informix - Problem description
| Problem IT04414 | Status: Closed |
CM FREQUENTLY LOGS MESSAGES ABOUT SERVER TYPES SWITCHING WHEN RUNNING AGAINST IDS 11.70 | |
| product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
| Problem description: | |
When running CSDK 4.10 against IDS server 11.70, the oncmsm logs the following messages frequently: 14:29:18 The server type of cluster hdr_test server pri1170fc7 is HDR. 14:29:18 The server type of cluster hdr_test server pri1170fc7 is Primary. 14:29:18 The server type of cluster hdr_test server pri1170fc7 is HDR. 14:29:18 The server type of cluster hdr_test server pri1170fc7 is Primary. 14:29:39 The server type of cluster hdr_test server pri1170fc7 is HDR. ...... | |
| Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of 11.70 server with 4.10 connection manager. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-12.10.xC5 * **************************************************************** | |
| Local Fix: | |
Use CM v 3.70 | |
| Solution | |
Problem Fixed In IDS-12.10.xC5 | |
| Workaround | |
not known / see Local fix | |
| Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 16.09.2014 16.10.2015 16.10.2015 |
| Problem solved at the following versions (IBM BugInfos) | |
| Problem solved according to the fixlist(s) of the following version(s) | |
| 12.10.xC5 |
|
| 12.10.xC5.W1 |
|